应用领域 发布时间: 2026-09-13 821 阅读

If the mask leaks even a little, the oxygen concentration will float away. Medical mask seals are too hard, so a ring of red marks on the face is a complaint first.

Conclusion first: mask sealing, sealing hypoallergenic seals tie together

Medical mask seals are "face-close components": sealed, in contact with skin, worn long-term.

Materials must be well sealed, hypoallergenic, and snug—conclusion first: SEBS-based TPE is mainstream for medical mask sealing; High allergenicity requirements, medical silicone is used.

The biggest pitfall in medical mask sealing: if the mold is fine, the material is left on the big pot. The mold has been inspected and fine, but the problem mostly lies with the material—the material is the final step in sealing.

Medical mask sealing is a functional component: leaking air causes oxygen concentration to float. Choosing the right material makes the mask stable—functional parts, don't skimp on material costs.

TPE Why is it for face fitting: sealing can be made, and hypoallergenic

Reasons for using TPE for medical mask sealing: sealing workable, low allergenicity, good adhesion, high efficiency—all four together, suitable for mask sealing.

Sealing is the core: no air leakage when fitting. Seal test is written into acceptance—leaks are a problem.

Low sensitivity can't be saved: Fit the face all day. Write allergy test into acceptance—allergy is the problem.

Wear it for a day and press it: fitting, skin, long-term

Fit condition: fits the face. Sealing test must be checked—air leakage is the problem.

Skin condition: contact with skin. Allergy data must be checked—allergy is the problem.

Long-term operation: wearing for a long time. Comfort data must be checked—indentation is the problem.

TPE or silicone: Check the seal for oxygen leakage

dimensionTPEsilicone
sealedgoodgood
low allergenicsuitablegood
FittingAdjustableGood
CostMediumMedium-High
EfficiencyInjection MoldingVulcanization
BatchStableStable

Table Reading: Silicone is low-sensitivity, good, but expensive, and vulcanizes slowly; TPE offers high cost performance—mainstream mask sealing TPE.

Highly sensitized silicone for people, conventional TPE—selected according to population

Sealing Practical Testing Three-Step Table: Bonding, Indentation, Disinfection

StepsContentPurpose
Assembly Actual TestOn-Machine TestSealing Test
Wearing TestReal Person Trying onInspection Adherence
Allergy TestSkin TestLow Allergy Test

Table Reading: First measure flash, then measure mold sticking, finally test sealing. After completing these three steps, it's clear which is between material and mold.

Actual testing is the method for checking the pot.

Two pitfalls: mold misconduct, seal fraud

Pit one: mold blaming. If the mold leaks after calibration, it's usually due to incorrect material flow or hardness—check the material first.

Plot two: False sealing label. The report says sealed, but actual air leaks — seal is accepted by actual measurement.

Pit 3: Allergy missed test. Allergy is the problem—allergy testing is mandatory.

Three acceptance questions: fit, low sensitivity, batch

Three questions: What standards are used for sealing, is there a sensitization test, and how is the fit tested? First inspection: Actual wear and testing—three questions and one inspection, supplier background is clear.

Material verification must come first: first check the flow curve and hardness of the material, then discuss the price—the material is the final step in sealing.

Make sampling a habit: keep samples for each batch, retest the seal for low sensitivity by batch. Compare batch material before scaling up—stable batches, fewer customer complaints.

Mask seal Shore A 30-40, soft and close to the face—too hard causes heavy indentation, too soft causes air leakage. Surgical mask worn for a few hours has a softer hardness; For short-term emergency masks, sealing is prioritized. Choose the mask type and set the hardness level for wearing duration.

After wearing the mask for several hours, a red mark appeared on my face—the seal was pressed too tight, and the material was too hard and didn't adhere. The tightness of the head strap and the hardness of the seal must match; neither end should be too extreme.

Heavy indentation isn't because the head strap is tight, but because the seal is too hard.

Don't blame the seal for leaks first—the head strap fit structure is wrong, the tightness isn't adjusted properly, and even the softer seal will leak. Check the fit structure first, then adjust the hardness. Mask leaks stem from the fit between the head strap and seal.

Select materials according to the actual disinfection method—wipe with alcohol, disinfect at high temperature, soak in disinfectant, and test each once. Inform the supplier about the headband structure and recommend hardness based on the fit structure.

Explain the disinfection method clearly so the formula is correct.

The mask seal is a 'soft gasket'—worn against the face for several hours, it needs to be both sealed and hypoallergenic. The low-allergen TPE surface has minimal leaching, so even when soaked in sweat, it doesn't cause redness. For skin-contact parts, low leaching is more important than low hardness.

Table of Common Problems and Countermeasures for Medical Mask Sealing

PhenomenonReasonCountermeasure
air leakInsufficient sealingAdjust cross-section
IndentationHigh hardnessReduce hardness
AllergyAllergenSwitch to hypoallergenic material
Transformationdisinfection corrosionChange to a durable disinfectant
Lack of coordinationStructural Designadjust the structure

The mask seal edge should be selected according to Shore A 30-40; too soft fits well but leaves heavy marks. Add a soft section at the nose bridge and a hard section at the cheeks, so the same seal edge has two hardness levels — fitting and comfort should be designed in separate sections.

Cologne Customer Case: Cost exceeded, quotes not competitive, customized grade back within budget

A medical device factory in Xiamen found that the cost of sealing materials for medical masks exceeded the budget, and their quotes were not competitive. Cologne cooperated to customize special grades resistant to oil and temperature, meeting performance standards, and bringing the cost back within the budget. Customizing according to the working conditions is the only way to reduce costs — if the cost exceeds the budget, first check whether the grade selection was too broad.

Summary

Selection of medical mask sealing: first inspect the material, then test the seal. If the mold is fine but the material is at fault, don’t let the mold take the blame.

Before pouring the material into the machine, what needed to be done was actually already completed.

How much to enhance, whether to add flame retardant, which level of temperature resistance to achieve, whether the size is stable—once these judgments are made, the particles just execute the conclusions.

Ningbo Cologne New Materials Co., Ltd. produces modified thermoplastic elastomers, modified nylons (PA6 / PA66 / PA46 / PA11 / PA12 / PA6T / PA9T and nylon alloys), modified PPO / PPS, as well as stock of nylon resins, secondary materials, and bulk materials from major chemical giants.